Back

PON1/364

Notification details

Status Completed
First observed date 05 May 2011
First observed time 08:00
Incident type(s) Chemical release
Organisations involved
Installation GSF Arctic III
Installation type Mobile
Field Beryl
Latitude 59° 32' 0.0'' N
Longitude 1° 26' 0.0'' E
Quadrant / block no. 9 / 13

Chemical 1

Chemical product released Houghton Stack magic EcoF, Houghton Commercial Monoetheylene Glycol
Total quantity of chemical released 184.1 kg

Formal investigation

Formal investigation ever opened No

Close off details

Release ever ongoing No

Source details

Source Leak at Blow Out Preventer shuttle valve.