IRS/2025/5989/PON10
Notification details
| Status | Completed |
|---|---|
| First observed date | 25 March 2025 |
| First observed time | 18:00 |
| Organisation involved | PERENCO UK LIMITED |
| Installation | Davy AMOSS Platform |
| Field | DAVY |
| Latitude | 53° 0' 18.0'' N |
| Longitude | 2° 53' 46.0'' E |
| Quadrant / block no. | 49 / 30 |
Breached conditions details
| Related to a breach of a condition of an approved Consent to Locate | Yes |
|---|---|
| Breach related to | Consent Condition and Marking Schedule Condition |
| Breached conditions | 5. During the Works, A 4. Fogs, A 3. Lights |
Fogs breached conditions
| Reduction in range of main fog signals | Yes |
|---|
Lights breached conditions
| Reduction in range of primary white lights | Yes |
|---|---|
| Secondary white lights lost | Yes |
| Subsidiary red lights lost | Yes |
Formal investigation
| Formal investigation ever opened | No |
|---|
Further details
| Installation fully compliant with its Consent to Locate conditions | Yes |
|---|---|
| Non-compliance reasons related to | Primary Power Supply |
| Loss of power | Yes, primary only |
| Loss of power date | 25 March 2025 |
| Loss of power time | 18:00 |